• AC Drives
  • Interference Control
Voltage Disturbance
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • Per Unit Calculator
    • Transformer Calculator
    • Line Reactor Calculator
    • Current Limiting Reactor Sizing Calculation
    • Power Factor Calculator
    • Motor Calculator
    • Voltage Unbalance Calculator
    • Voltage Divider Calculator 3 Resistors
    • AC Voltage Drop With Power Factor
    • Resonance Calculator
    • Motor Starting Calculator
    • Delta Wye Conversion Calculator
    • Harmonic Filter Calculator
    • PT Ratio Calculation
    • Current Unbalance Calculator
    • Transformer Tap Changer Calculator
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • - Per Unit Calculator
    • - Transformer Calculator
    • - Line Reactor Calculator
    • - Current Limiting Reactor Sizing Calculation
    • - Power Factor Calculator
    • - Motor Calculator
    • - Voltage Unbalance Calculator
    • - Voltage Divider Calculator 3 Resistors
    • - AC Voltage Drop With Power Factor
    • - Resonance Calculator
    • - Motor Starting Calculator
    • - Delta Wye Conversion Calculator
    • - Harmonic Filter Calculator
    • - PT Ratio Calculation
    • - Current Unbalance Calculator
    • - Transformer Tap Changer Calculator

SURGE IMPEDANCE LOADING OF TRANSMISSION LINE

Surge impedance loading [SIL] of a transmission system is the power delivered by a lossless line to a purely resistive…

Read More

August 21, 2022

Difference between Control Power Transformer and Potential Transformer

Control Power Transformer Control power transformers [CPT] are transformers designed to provide control voltage to contactors, starter control panels, solenoids,…

Read More

July 30, 2022
Neutral Current Transformer or Neutral Current Sensor

NEUTRAL CURRENT TRANSFORMER APPLIED WITH ELECTRONIC TRIP UNITS

Neutral Current Transformer [NCT] is required for residual ground fault detection and power metering in three-phase four wires systems. Residual…

Read More

July 18, 2022

INCORRECT MOTOR CONTROL CIRCUIT WIRING

Motor control circuits are typically fed from motor phase wiring by tapping phase circuits with control power transformer. This control…

Read More

July 10, 2022
Electric field Overstress on insulation due to unshielded power cable touching a grounded surface

Non-Shielded Medium Voltage Cable

National Electric Code [NEC] 2005 edition and later editions requires shielded medium voltage [MV] cables for all circuits operating above…

Read More

July 1, 2022
Zero Sequence Current Transformers

Zero Sequence Current Transformer

Zero Sequence Current Transformer [ZSCT] also known as Core Balance Current Transformer [CBCT] is a type of current transformer [CT]…

Read More

June 30, 2022

Percentage insulation level of medium voltage cables

Medium Voltage [MV] cable insulation is made of different variations of extruded solid or laminar (oil paper). Most common insulation…

Read More

June 28, 2022
Winding connections for transformer with four taps

Transformer Tap Changer: How to Select Transformer Taps?

Taps are provided on a transformer to adjust secondary voltage of power transformer for high or low voltage conditions. Common…

Read More

December 7, 2021

CURRENT UNBALANCE: CAUSES, EFFECTS AND PROTECTION

In three phase systems, current unbalance is defined as the maximum deviation of any phase current from average divided by…

Read More

November 23, 2021

THREE-PHASE TO GROUND SHORT CIRCUIT WAVEFORM

Characteristics of a Three Phase to Ground fault Following are some of the characteristic ‘signatures’ of a three phase to…

Read More

November 13, 2021
  • 4
  • 5
  • 6
  • 7
  • 8
“To invent, you need a good imagination and a pile of junk.” – Thomas A. Edison
  • About Us
  • Disclaimer
  • Contact Us