• AC Drives
  • Interference Control
Voltage Disturbance
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • Per Unit Calculator
    • Transformer Calculator
    • Line Reactor Calculator
    • Current Limiting Reactor Sizing Calculation
    • Power Factor Calculator
    • Motor Calculator
    • Voltage Unbalance Calculator
    • Voltage Divider Calculator 3 Resistors
    • AC Voltage Drop With Power Factor
    • Resonance Calculator
    • Motor Starting Calculator
    • Delta Wye Conversion Calculator
    • Harmonic Filter Calculator
    • PT Ratio Calculation
    • Current Unbalance Calculator
    • Transformer Tap Changer Calculator
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • - Per Unit Calculator
    • - Transformer Calculator
    • - Line Reactor Calculator
    • - Current Limiting Reactor Sizing Calculation
    • - Power Factor Calculator
    • - Motor Calculator
    • - Voltage Unbalance Calculator
    • - Voltage Divider Calculator 3 Resistors
    • - AC Voltage Drop With Power Factor
    • - Resonance Calculator
    • - Motor Starting Calculator
    • - Delta Wye Conversion Calculator
    • - Harmonic Filter Calculator
    • - PT Ratio Calculation
    • - Current Unbalance Calculator
    • - Transformer Tap Changer Calculator

Percentage insulation level of medium voltage cables

Medium Voltage [MV] cable insulation is made of different variations of extruded solid or laminar (oil paper). Most common insulation…

Read More

June 28, 2022
Winding connections for transformer with four taps

Transformer Tap Changer: How to Select Transformer Taps?

Taps are provided on a transformer to adjust secondary voltage of power transformer for high or low voltage conditions. Common…

Read More

December 7, 2021

CURRENT UNBALANCE: CAUSES, EFFECTS AND PROTECTION

In three phase systems, current unbalance is defined as the maximum deviation of any phase current from average divided by…

Read More

November 23, 2021

THREE-PHASE TO GROUND SHORT CIRCUIT WAVEFORM

Characteristics of a Three Phase to Ground fault Following are some of the characteristic ‘signatures’ of a three phase to…

Read More

November 13, 2021
Ice Cube Relay

RELAY CONTACT ARCING WAVEFORM

When current flow through inductive circuit is interrupted, voltage proportional to V= L (di/dt) is produced. This voltage can be…

Read More

October 17, 2021

Current Transformer Failure Due to Capacitor Bank Discharge Current

Current Transformer (CT) failure can be due to many reasons some of which are contamination, open circuit secondary, incorrect application…

Read More

October 2, 2021
Parts of Rogowski Coil

Rogowski Coil Flexible Current Transformer

Flexible current transformer is also known as Rogowski coil. What is a Rogowski Coil? Rogowski coil is an electric current…

Read More

September 26, 2021

Isolated Ground Receptacle

When interference from electromagnetic sources needs to be managed on the ground circuit of a particular load or sensitive electronic…

Read More

September 19, 2021
Cable TV shield is connected to electrical ground

Open Neutral: Voltage Fluctuation and Stray Voltage

Open neutral or broken neutral on a service transformer or service cable into a facility can result in serious overvoltage…

Read More

May 24, 2021

Current Transformer DC Saturation and Time to Saturate

Saturation of current transformers (CT) when carrying high magnitude current is a well-known phenomenon. Usually symmetrical fault current is used…

Read More

May 11, 2021
  • 4
  • 5
  • 6
  • 7
  • 8