• AC Drives
  • Interference Control
Voltage Disturbance
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • Per Unit Calculator
    • Transformer Calculator
    • Line Reactor Calculator
    • Current Limiting Reactor Sizing Calculation
    • Power Factor Calculator
    • Motor Calculator
    • Voltage Unbalance Calculator
    • Voltage Divider Calculator 3 Resistors
    • AC Voltage Drop With Power Factor
    • Resonance Calculator
    • Motor Starting Calculator
    • Delta Wye Conversion Calculator
    • Harmonic Filter Calculator
    • PT Ratio Calculation
    • Current Unbalance Calculator
    • Transformer Tap Changer Calculator
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • - Per Unit Calculator
    • - Transformer Calculator
    • - Line Reactor Calculator
    • - Current Limiting Reactor Sizing Calculation
    • - Power Factor Calculator
    • - Motor Calculator
    • - Voltage Unbalance Calculator
    • - Voltage Divider Calculator 3 Resistors
    • - AC Voltage Drop With Power Factor
    • - Resonance Calculator
    • - Motor Starting Calculator
    • - Delta Wye Conversion Calculator
    • - Harmonic Filter Calculator
    • - PT Ratio Calculation
    • - Current Unbalance Calculator
    • - Transformer Tap Changer Calculator

Circuit Breaker Trip Due To Control Circuit Ground Fault

Control circuit for medium and high voltage circuit breakers have protective relay contacts to trip and close circuit breaker. Control…

Read More

January 30, 2024

Series Connection of Current Transformer

Series connection of current transformer [CT] is used when accuracy improvement is desired without increasing CT ratio. Series connection of…

Read More

November 27, 2023

What is a Capacitor Trip Device?

Capacitor trip device [CTD] or capacitor trip unit [CTU] is a device that provide DC source of energy for circuit…

Read More

November 20, 2023

What is Separately and Non-Separately Derived System?

A separately derived system is an electrical system in which the service phase (hot) and neutral conductors has no electrical…

Read More

October 16, 2023
Padmount transformer, three phases plus neutral

What is Main Bonding Jumper and Neutral Disconnect Link?

Main Bonding Jumper [MBJ] is used to connect switchboard neutral bus and switchboard ground bus. MBJ is a very critical…

Read More

October 14, 2023
PT100 RTD (2 wire + shield) sensor for motor winding

Over temperature protection using RTD

Temperature is the most common cause behind power system device damage. Expensive devices such as motors and transformers can have…

Read More

October 9, 2023
CT installed in switchgear

HOW DOES CT OPEN CIRCUIT PROTECTOR WORK?

Open circuiting secondary side of current transformer [CT] can lead to dangerous voltage build up that can eventually lead to…

Read More

October 6, 2023

Motor Over Temperature Protection

Temperature kills motors. Temperature is the most common cause behind motor damage. A 10-degree centigrade increase in insulation temperature decrease…

Read More

September 22, 2023
Two CTs

Three Phase Current Metering using Two Current Transformers

It is possible to do three phase current measurement using just two current transformers (CT) in electrical systems with neutrals…

Read More

September 8, 2023
Six pole CT shorting block in shorted position.

WHY ARE CT SHORTING BLOCKS USED?

Current Transformer [CT] shorting blocks are used to bypass CT secondary current flowing to the connected device by inserting a…

Read More