• AC Drives
  • Interference Control
Voltage Disturbance
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • Per Unit Calculator
    • Transformer Calculator
    • Line Reactor Calculator
    • Current Limiting Reactor Sizing Calculation
    • Power Factor Calculator
    • Motor Calculator
    • Voltage Unbalance Calculator
    • Voltage Divider Calculator 3 Resistors
    • AC Voltage Drop With Power Factor
    • Resonance Calculator
    • Motor Starting Calculator
    • Delta Wye Conversion Calculator
    • Harmonic Filter Calculator
    • PT Ratio Calculation
    • Current Unbalance Calculator
    • Transformer Tap Changer Calculator
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • - Per Unit Calculator
    • - Transformer Calculator
    • - Line Reactor Calculator
    • - Current Limiting Reactor Sizing Calculation
    • - Power Factor Calculator
    • - Motor Calculator
    • - Voltage Unbalance Calculator
    • - Voltage Divider Calculator 3 Resistors
    • - AC Voltage Drop With Power Factor
    • - Resonance Calculator
    • - Motor Starting Calculator
    • - Delta Wye Conversion Calculator
    • - Harmonic Filter Calculator
    • - PT Ratio Calculation
    • - Current Unbalance Calculator
    • - Transformer Tap Changer Calculator

Sequence Components

What are positive, negative, zero sequence components in power system and how do you calculate them? Three phase electric power…

Read More

June 29, 2018

Reactive Power Measurement

Reactive power is the power required by inductive devices (motors, transformers etc.) in power system to create magnetic field necessary…

Read More

June 26, 2018

Neutral Inversion and Neutral Displacement

Neutral inversion, Neutral shift or Neutral voltage displacement is the phenomenon in which the imaginary neutral of an ungrounded system…

Read More

June 25, 2018
6 pulse waveform with unbalanced voltage

Line Reactor vs Isolation Transformer

Line Reactor Line reactor as used in VFD/VSD application is an inductive component used in the line side or supply…

Read More

June 22, 2018
Waveform Phase Shift

Calculating Phase Difference Between Two Waves

Often we will have two sinusoidal or other periodic waveforms having the same frequency, but is phase shifted. To calculate…

Read More

June 22, 2018

Troubleshooting VFD Problems – How to Measure DC Bus Voltage and DC Ripple

Introduction: Some of the frequent and troublesome VFD faults are related to the DC bus voltage. The VFD control circuit…

Read More

June 17, 2018

Troubleshooting VFD Problems – Overvoltage Fault

Drive (VFD) overvoltage protection for common low HP drives is based on the measured voltage on the DC bus of…

Read More

June 10, 2018

Line Reactor vs DC Choke

Line Reactor Line reactor as used in VFD/VSD application is an inductive component used in the line side or supply…

Read More

June 4, 2018
Drive schematic showing DC bus

DC Choke for VFD

A DC choke (DC Link Choke) is used between the rectifier section and the bus capacitor section of a variable…

Read More

June 2, 2018

Medium Voltage Cable Construction

A power cable could appear as a simple electrical device, a conductor wrapped in an insulation. However, as you can…

Read More