• AC Drives
  • Interference Control
Voltage Disturbance
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • Per Unit Calculator
    • Transformer Calculator
    • Line Reactor Calculator
    • Current Limiting Reactor Sizing Calculation
    • Power Factor Calculator
    • Motor Calculator
    • Voltage Unbalance Calculator
    • Voltage Divider Calculator 3 Resistors
    • AC Voltage Drop With Power Factor
    • Resonance Calculator
    • Motor Starting Calculator
    • Delta Wye Conversion Calculator
    • Harmonic Filter Calculator
    • PT Ratio Calculation
    • Current Unbalance Calculator
    • Transformer Tap Changer Calculator
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • - Per Unit Calculator
    • - Transformer Calculator
    • - Line Reactor Calculator
    • - Current Limiting Reactor Sizing Calculation
    • - Power Factor Calculator
    • - Motor Calculator
    • - Voltage Unbalance Calculator
    • - Voltage Divider Calculator 3 Resistors
    • - AC Voltage Drop With Power Factor
    • - Resonance Calculator
    • - Motor Starting Calculator
    • - Delta Wye Conversion Calculator
    • - Harmonic Filter Calculator
    • - PT Ratio Calculation
    • - Current Unbalance Calculator
    • - Transformer Tap Changer Calculator

HOW TO CONNECT DC POWER SUPPLIES IN SERIES, PARALLEL AND REDUNDANT CONFIGURATION?

DC power supplies may be connected in series, parallel or redundant configuration depending on the application need. When higher voltage…

Read More

January 26, 2025

Difference Between ELV, SELV, PELV and FELV

ELV stands for Extra Low Voltage and is indicative of systems operating under 50VAC or 120VDC (ripple free). ELV systems…

Read More

January 21, 2025

What happens when Phase and Neutral are reversed ?

There are some regions of the world such as North America, where polarized receptacles are used, while other parts of…

Read More

March 28, 2024

Telephone Interference Factor

Harmonic voltage and current present in power system can negatively affect the quality of reception of telephone and other communication…

Read More

November 29, 2023

Capacitor bank discharge methods

Capacitor bank can hold dangerous voltage after disconnecting from power system unless discharging devices are connected to the capacitor terminals.…

Read More

October 31, 2023

What is the electrical resistance of human body?

Electrical resistance of human body has been estimated to be 1,000 Ω according to IEEE Std. 80 standard. Resistance is…

Read More

October 21, 2023

STRAY VOLTAGE – HOW DOES IT ORIGINATE?

Stray voltage is defined by IEEE as “A voltage resulting from the normal delivery and/or use of electricity (usually smaller than…

Read More

March 19, 2023

POWER QUALITY CHECK USING MULTIMETER

This article discusses methods to measure basic power (Voltage) quality parameters using a multimeter. Using any advanced digital multimeter (similar…

Read More

November 7, 2022
Parts of Rogowski Coil

Rogowski Coil Flexible Current Transformer

Flexible current transformer is also known as Rogowski coil. What is a Rogowski Coil? Rogowski coil is an electric current…

Read More

September 26, 2021

Isolated Ground Receptacle

When interference from electromagnetic sources needs to be managed on the ground circuit of a particular load or sensitive electronic…

Read More

September 19, 2021