• AC Drives
  • Interference Control
Voltage Disturbance
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • Per Unit Calculator
    • Transformer Calculator
    • Line Reactor Calculator
    • Current Limiting Reactor Sizing Calculation
    • Power Factor Calculator
    • Motor Calculator
    • Voltage Unbalance Calculator
    • Voltage Divider Calculator 3 Resistors
    • AC Voltage Drop With Power Factor
    • Resonance Calculator
    • Motor Starting Calculator
    • Delta Wye Conversion Calculator
    • Harmonic Filter Calculator
    • PT Ratio Calculation
    • Current Unbalance Calculator
    • Transformer Tap Changer Calculator
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • - Per Unit Calculator
    • - Transformer Calculator
    • - Line Reactor Calculator
    • - Current Limiting Reactor Sizing Calculation
    • - Power Factor Calculator
    • - Motor Calculator
    • - Voltage Unbalance Calculator
    • - Voltage Divider Calculator 3 Resistors
    • - AC Voltage Drop With Power Factor
    • - Resonance Calculator
    • - Motor Starting Calculator
    • - Delta Wye Conversion Calculator
    • - Harmonic Filter Calculator
    • - PT Ratio Calculation
    • - Current Unbalance Calculator
    • - Transformer Tap Changer Calculator

TRANSFORMER CONNECTIONS AND THIRD HARMONIC COMPONENTS

When a power transformer is connected to an AC voltage source, a small primary current known as excitation current will…

Read More

January 9, 2026

CORNER GROUNDED DELTA TRANSFORMER CONNECTION

Ungrounded delta secondary connected transformers were used extensively in the early era of industrial electrical distribution. Ability to operate machinery…

Read More

May 27, 2024

IMPORTANCE OF TRANSFORMER CORE GROUNDING

Laminated steel core of a power transformer is insulated from ground and is typically referenced to ground (earth) at a…

Read More

May 11, 2024

PARAMETERS THAT DETERMINE TRANSFORMER INRUSH CURRENT

High magnitude current lasting few power cycles during switching on a power transformer is known as transformer inrush current. Magnitude…

Read More

April 18, 2021

Transformer Short Circuit Test

Short circuit test is performed on a transformer to measure the equivalent series resistance and reactance. Series resistance provides information…

Read More

November 26, 2020

Types of Transformer Cooling

Power transformers can have different kVA depending on the type of cooling method used. Heat is one of the main…

Read More