• AC Drives
  • Interference Control
Voltage Disturbance
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • Per Unit Calculator
    • Transformer Calculator
    • Line Reactor Calculator
    • Current Limiting Reactor Sizing Calculation
    • Power Factor Calculator
    • Motor Calculator
    • Voltage Unbalance Calculator
    • Voltage Divider Calculator 3 Resistors
    • AC Voltage Drop With Power Factor
    • Resonance Calculator
    • Motor Starting Calculator
    • Delta Wye Conversion Calculator
    • Harmonic Filter Calculator
    • PT Ratio Calculation
    • Current Unbalance Calculator
    • Transformer Tap Changer Calculator
  • Power Engineering
  • Power Quality
  • Grounding
  • Engineering Calculators
    • - Per Unit Calculator
    • - Transformer Calculator
    • - Line Reactor Calculator
    • - Current Limiting Reactor Sizing Calculation
    • - Power Factor Calculator
    • - Motor Calculator
    • - Voltage Unbalance Calculator
    • - Voltage Divider Calculator 3 Resistors
    • - AC Voltage Drop With Power Factor
    • - Resonance Calculator
    • - Motor Starting Calculator
    • - Delta Wye Conversion Calculator
    • - Harmonic Filter Calculator
    • - PT Ratio Calculation
    • - Current Unbalance Calculator
    • - Transformer Tap Changer Calculator

Medium Voltage Cable Construction

A power cable could appear as a simple electrical device, a conductor wrapped in an insulation. However, as you can…

Read More

May 19, 2018

Ferroresonant Transformer

What is a Ferroresonant transformer? Ferroresonant transformer also known as Constant Voltage Transformer (CVT) is used to provide: Voltage sag…

Read More

April 15, 2018

Voltage Sag due to Induction motor starting

Motor Starting Current: Induction motor starting on full voltage (also known as across the line starting or direct on-line starting)…

Read More

April 1, 2018

AC Voltage Drop and System Power Factor

Flow of DC current through a resistance result in voltage drop according to ohms law. For AC circuits, in addition…

Read More

March 20, 2018

Voltage Regulation

  To engineers, ‘regulation’ means variation of output speed or voltage as the load on that device is increased from…

Read More

February 21, 2018

Phase Sequence and Phase Angle

Phase rotation or phase sequence is a concept that is not well understood and misapplied in many installations. Lets dive…

Read More

February 18, 2018

Scott T Transformer

Scott connection is a method of achieving 3 phase to 2 -phase transformation by using two single-phase transformers. 

…

Read More

January 25, 2018

Transformer Impedance : Why is impedance in percentage?

Ever wondered what is the %Z or %impedance or short circuit impedance that everyone refers to when talking about power…

Read More